R/jacob_lohman_utilities.R
jacob_lohman_F_solution_initial.Rd
Function to calculate the initial parameters of aconstant head aquifer (artesian aquifer) using the Jacob-Lohman solution
jacob_lohman_F_solution_initial(ptest)
ptest | A pumping_test object |
---|
A list with
a : Slope of the straight line fitted to the drawdown data using the Cooper-Jacob approach
t0 : Intercept of the straight line fitted to the drawdown data using the Cooper-Jacob approach
Jacob, C. E. & Lohman, S. W. Nonsteady Flow to a Well Of Constant Drawdown. American Geophysical Union, 1952, 33, 10.
Other jacob_lohman functions: jacob_lohman_F_calculate_parameters
,
jacob_lohman_F_solution
,
jacob_lohman_F_well_function
,
jacob_lohman_G_WF_LT
,
jacob_lohman_G_calculate_parameters
,
jacob_lohman_G_solution_initial
,
jacob_lohman_G_solution
,
jacob_lohman_G_well_function
,
jacob_lohman_WF_F_LT
data(jacob_lohman) s <- vector("numeric", length(jacob_lohman$t)) s[1:length(jacob_lohman$t)] <- 0 ptest <- pumping_test("Well1", Q = jacob_lohman$q, r = 0.84, t = jacob_lohman$t, s = s)#> Warning: the condition has length > 1 and only the first element will be usedptest$additional_parameters <- list(rw = 0.084, s0 = 28.142) sol0 <- jacob_lohman_F_solution_initial(ptest) print(sol0)#> $a #> [1] 443.0971 #> #> $t0 #> [1] 60 #>