Function to calculate the theis well function for values of \(u > 1\)
theis_well_function_large(u)
u | Dimensionless \(u\) variable defined as: $$ u=\frac{r^{2}S}{4Tt} $$ where \(r\) is the distance between the pumping and observation well in m, \(S\) is the storage coefficient (dimensionless), \(T\) is the Transmisivity in m2/s and \(t\) is the time in s |
---|
This function returns the value of the dimensionless drawdown
Theis, C. The relation between the lowering of the piezometric surface and the rate and duration of discharge of a well using groundwater storage. Transactions of the American Geophysical Union, 1935, 2, 519-524
Other theis functions: exponential_integral
,
theis_WF_LT_dlogt
,
theis_WF_LT
,
theis_calculate_parameters
,
theis_solution_dlogt
,
theis_solution_initial
,
theis_solution
,
theis_well_function_small
,