Function to calculate the hydraulic parameters of the Papadopulos-Cooper solution

papadopulos_cooper_calculate_parameters(ptest, par, hydraulic = TRUE)

Arguments

ptest

A pumping test object

par

A list with the values of a (slope) and t0 (Intercept) of the straight line fitted to the drawdown data using the Cooper-Jacob approach.

hydraulic

Logical flag to indicate if hydraulic parameters are calculated. If False, the the statistcal parameters (a and t0) are calculated.

Value

A list with the hydraulic parameters:

  • Tr: Transmissivity

  • Ss: Storage coefficient

  • cd: Wellbore Storage

  • rho: Dimensionless radius

References

Papadopulos, I. S. & Cooper, H. H. Drawdown in a well of large diameter. Water Resources Research, 1967, 3, 241-244.

See also

Examples

data(papadopulos_cooper) ptest <- pumping_test("Well1", Q=0.0050472, r = 3.048, t = as.numeric(papadopulos_cooper$t), s = papadopulos_cooper$s) par <- list(rw = 0.6096, rc = 0.6096 ) ptest$additional_parameters <- par sol0 <- papadopulos_cooper_solution_initial(ptest) pc.par <- papadopulos_cooper_calculate_parameters(ptest, sol0) print(pc.par)
#> $Tr #> [1] 0.0008732865 #> #> $Ss #> [1] 0.004969532 #> #> $cd #> [1] 100.6131 #>