Function to calculate the hydraulic parameters for the Neuzil solution
neuzil_calculate_parameters(ptest, par, hydraulic = TRUE)
ptest | A pumping_test object |
---|---|
par | A list with the wellbore storage coefficient (cd) and t0 parameters |
hydraulic | Logical flag to indicate if hydraulic parameters are calculated. If False, the the statistcal parameter (a and t0) are calculated. |
A list with
Tr: Transmissivity
Ss: Storage coefficient
radius_influence
Neuzil, C. E. On conducting the modified 'Slug' test in tight formations. Water Resources Research, 1982, 18, 2, 439-441
Other neuzil functions: neuzil_WF_LT
,
neuzil_solution_dlogt
,
neuzil_solution_initial
,
neuzil_solution
,
neuzil_well_function
data(neuzil) ptest.neuzil <- pumping_test("Well1", Q = 0, r = 0.0, t = neuzil$t, s = neuzil$s) par <- list(rw = 0.067, ceff = 2.723e-9, vs = 1.59) ptest.neuzil$additional_parameters <- par sol0 <- neuzil_solution_initial(ptest.neuzil) neuzil.par <- neuzil_calculate_parameters(ptest.neuzil, sol0) print(neuzil.par)#> $Tr #> [1] 2.941765e-09 #> #> $Ss #> [1] 3.008648e-05 #> #> $radius_influence #> [,1] #> [1,] 0.1615661 #>