The information for this pumping test is:

  • Radius of the well (in m): rw <- 0.6096

  • Radius of the casing (in m): rc <- 0.6096

  • Distance to pumping well (in m): r <- 3.048

  • Pumping Rate (in m3/s): Q <- 0.0050472

papadopulos_cooper

Format

A data frame with 46 rows and 2 variables:

t

time, in seconds

s

drawdown, in meters

Source

Hall, P. Water well and aquifer test analysis 1996, Water Resources Publications, LLC, 412 pp. Pages 171-174.