The information for this slug test is:
Radius of the well (in m): rw <- 0.071
Radius of the casing (in m): rc <- 0.025
cooper_slug
A data frame with 69 rows and 2 variables:
time, in seconds
drawdown, in meters
Butler James, 1998, The design, performance and analysis of slug tests. Lewis Publisher. Table 5.2 pp. 61-62.
Localisation: Test performed in a monitoring well in Lincoln County, Kansas Geology. The well was screened in a deltaic sequence consisting of mudstone interbedded with very fine sandstone.